Operating Temperature -45°C~55°C
Packaging Tray
Published 2002
Series KRPA
Part Status Active
Moisture Sensitivity Level (MSL) Not Applicable
Termination Plug
ECCN Code EAR99
Additional Feature COIL OPERATE VOLTAGE(AC): 20.4 V
Depth 37.3mm
Current Rating 10A
Reference Standard CSA; UL
Termination Style Plug In, 11 Pin (Octal)
Voltage - Rated AC 240V
Approval Agency CSA, UL
Physical Dimension 48.8mm x 37.3mm x 34.9mm
Insulation Resistance 1000000000Ohm
ELV Non-Compliant
Max Voltage Rating (AC) 240V
Electrical Life 10000000 Cycle(s)
Throw Configuration 3PDT
Contact Form 3PDT (3 Form C)
Relay Type General Purpose
Coil Resistance 85Ohm
Operate Time 15 ms
Coil Voltage 24VAC
Coil Type Non Latching
Switching Voltage 240VAC -Max
Coil Current 84mA
Release Time 10 ms
Must Operate Voltage 20.4VAC
Power Consumption 2W
Coil Power 2.1W
Contact/Output Supply Type AC
Relay Action MOMENTARY
Coil/Input Supply Type AC
Coil Voltage (AC) 24V
Dielectric Strength Between Open Contacts 1000 Vrms
Coil Insulation Class B
Dielectric Strength Between Coil and Contacts 1000 Vrms
Contact Voltage Rating (AC) 240V