Operating Temperature 0°C~70°C TA
Packaging Tube
Published 2010
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Type Simple Reset/Power-On Reset
Max Power Dissipation 330mW
Base Part Number MAX6301
Output Open Drain or Open Collector
Operating Supply Voltage 5V
Max Supply Voltage 5.5V
Min Supply Voltage 1V
Watchdog Timer Yes
Reset Active Low
Voltage - Threshold Adjustable/Selectable
Number of Voltages Monitored 1
Reset Timeout 2.8ms Minimum
Min Reset Threshold Voltage 1.195V
Max Reset Threshold Voltage 1.245V